Product Overview

Category

The P51-500-A-U-I36-20MA-000-000 belongs to the category of industrial pressure transmitters.

Use

It is used for measuring and transmitting pressure in industrial applications.

Characteristics

  • High accuracy
  • Robust construction
  • Wide operating temperature range
  • Compatibility with various industrial processes

Package

The product is typically packaged in a protective casing to ensure durability during transportation and installation.

Essence

The essence of the P51-500-A-U-I36-20MA-000-000 lies in its ability to provide precise and reliable pressure measurements in industrial settings.

Packaging/Quantity

The product is usually packaged individually and is available in single-unit quantities.

Specifications

  • Pressure Range: 0-500 psi
  • Output Signal: 4-20 mA
  • Operating Temperature: -40°C to 85°C
  • Material: Stainless steel
  • Electrical Connection: Integral cable

Detailed Pin Configuration

The detailed pin configuration of the P51-500-A-U-I36-20MA-000-000 includes: 1. Power supply input (+) 2. Power supply input (-) 3. Signal output 4. Not connected

Functional Features

  • High precision pressure sensing
  • Linear output proportional to pressure
  • Built-in temperature compensation
  • Overpressure protection

Advantages

  • Reliable and accurate pressure measurement
  • Suitable for harsh industrial environments
  • Long-term stability
  • Easy integration into existing systems

Disadvantages

  • Limited pressure range compared to some other models
  • Requires periodic calibration and maintenance

Working Principles

The P51-500-A-U-I36-20MA-000-000 operates on the principle of strain gauge technology, where changes in pressure cause deformation in the sensing element, leading to a change in electrical resistance. This change is then converted into a standardized electrical signal (4-20 mA) proportional to the applied pressure.

Detailed Application Field Plans

The P51-500-A-U-I36-20MA-000-000 is well-suited for applications such as: - Hydraulic systems - Pneumatic systems - Industrial process control - Pressure monitoring in manufacturing plants

Detailed and Complete Alternative Models

Some alternative models to the P51-500-A-U-I36-20MA-000-000 include: - P51-100-A-U-I36-20MA-000-000 (0-100 psi range) - P51-1000-A-U-I36-20MA-000-000 (0-1000 psi range) - P51-1000-B-U-I36-20MA-000-000 (0-1000 bar range)

In conclusion, the P51-500-A-U-I36-20MA-000-000 industrial pressure transmitter offers high precision and reliability in measuring pressure in various industrial applications, making it an essential component in ensuring operational efficiency and safety.

Word Count: 411

Enumerați 10 întrebări și răspunsuri comune legate de aplicarea lui P51-500-A-U-I36-20MA-000-000 în soluțiile tehnice

  1. What is the application of P51-500-A-U-I36-20MA-000-000?

    • The P51-500-A-U-I36-20MA-000-000 is a pressure transducer commonly used for measuring and monitoring pressure in various technical solutions.
  2. How does P51-500-A-U-I36-20MA-000-000 work?

    • This pressure transducer works by converting the applied pressure into an electrical signal, typically a 4-20mA output, which can be used for further processing and control.
  3. What are the typical industries that use P51-500-A-U-I36-20MA-000-000?

    • Industries such as HVAC, automotive, aerospace, industrial automation, and process control commonly utilize the P51-500-A-U-I36-20MA-000-000 for pressure measurement applications.
  4. What is the pressure range of P51-500-A-U-I36-20MA-000-000?

    • The pressure range of P51-500-A-U-I36-20MA-000-000 can vary, but it is commonly available in ranges from a few psi to several thousand psi, depending on the specific model.
  5. Can P51-500-A-U-I36-20MA-000-000 be used in harsh environments?

    • Yes, the P51-500-A-U-I36-20MA-000-000 is designed to withstand harsh environmental conditions and is often used in applications where exposure to extreme temperatures, moisture, or vibration is a concern.
  6. What are the key features of P51-500-A-U-I36-20MA-000-000?

    • Some key features include high accuracy, robust construction, compatibility with various media, and options for electrical outputs and pressure connections.
  7. Is calibration required for P51-500-A-U-I36-20MA-000-000?

    • Yes, periodic calibration is recommended to ensure accurate and reliable performance of the pressure transducer.
  8. Can P51-500-A-U-I36-20MA-000-000 be integrated with control systems?

    • Yes, it can be easily integrated with control systems and PLCs due to its standardized 4-20mA output signal.
  9. Are there any special installation considerations for P51-500-A-U-I36-20MA-000-000?

    • Proper mounting and sealing techniques should be followed to ensure accurate pressure measurement and to protect the transducer from damage.
  10. What are the common troubleshooting steps for P51-500-A-U-I36-20MA-000-000?

    • Troubleshooting may involve checking for proper electrical connections, verifying the pressure input, and ensuring that the transducer is within its specified operating conditions.